Complete product listing
Din Rail mount
Datexel manufactures the largest range of din rail mountable signal conditioners, head mount and din rail temperature transmitters, isolators and trip amplifiers.
The units can be fixed range, dip switch programmable or pc programmable.
Signal Converters Fixed Low Cost
Signal Converters Dip Switch Programmable
Signal Converters and Transmitter "Slim Line"
Signal Converters and Transmitter "Smart Line"
Signal Converters DAT200 The DAT200 series of transmitters and converters can accept input signals from potentiometers, voltage or current signals. The 2 wire is loop powered and 3 wire has a voltage or current output.
| DAT205 2W | 2Wire Loop Powered Converter for Potentiometer. Input: Potentiometer Output: 4-20 mA Power Supply: Loop |
| DAT205 3W | 3 Wire Voltage, Current output. Potentiometer input. Input: Potentiometer Output: Voltage or 4-20mA Power Supply: 18 -30 Vdc |
| DAT207A 2W | 2Wire Loop Powered Converter for mV. Input: mV. Output: 4-20 mA Power Supply: Loop |
| DAT207A 3W | 3 Wire Voltage, Current output. Voltage, Current input. Input: mV. Output: Voltage or 4-20mA Power Supply: 18 -30 Vdc |
| DAT207B 2W | 2Wire Loop Powered Converter for mV. Input: mV, or Volts. Output: 4-20 mA Power Supply: Loop |
| DAT207B 3W | 3 Wire Voltage, Current output. Voltage, Current input. Input: mV, or Volts. Output: Voltage or 4-20mA Power Supply: 18 - 30 Vdc |
| DAT207C 2W | 2Wire Loop Powered Converter for mV. Input: mA. Output: 4-20 mA Power Supply: Loop |
| DAT207C 3W | 3 Wire Voltage, Current output. Voltage, Current input. Input: mA. Output: Voltage or 4-20mA Power Supply: 18 - 30 Vdc |
Loop Powered Isolator DAT511 The DAT500 series of self-powered galvanic isolators provide isolation between grounds. The DAT511H is suitable for Hart applications.
| DAT511 |
Input: mA. Output: 4-20 mA Power Supply: Loop |
| DAT511H | Self Powered Loop Isolator. Suitable for HART applications. Input: mA. Output: 4-20 mA Power Supply: Loop |
Slim Series: Temperature and Signal Converters The new line of converters that provides the highest flexibility in signal conversion.
| DAT4530 | Universal isolated converter configurable by dip-switch or PC double output & trip amplifier. Input: mA, Volts,Resistance, RTD's, and Thermocouples. Output: Volts, mA, Relay. Power Supply: 20 - 30 Vdc Isolation : Yes Trip Amp : Yes Square Root Extraction : Yes Programmable : Dip Switch and PC Dual Output : Yes |
| DAT4531A | Isolated converter for Tc and mV configurable by Dip-Switch or PC Input: Thermocouples and mV. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC |
| DAT4531B | Isolated converter for RTD and resistance configurable by Dip-Switch or PC Input: RTD's. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC |
| DAT4531C | Isolated converter for PTC/NTC/Pot configurable by Dip-Switch or PC Input: PTC/NTC, Potentiometer. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC |
| DAT4531D | Isolated converter for voltage and current configurable by Dip-Switch or PC Input: Volts and mA. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC |
| DAT4532A | Double channel, isolated converter for Tc and mV configurable by Dip-Switch or PC Input: Thermocouples and mV. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Channel : Yes |
| DAT4532B | Double channel, isolated converter for RTD and resistance configurable by Dip-Switch or PC Input: RTD's. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Channel : Yes |
| DAT4532C | Isolated, double channel converter for PTC/NTC/Pot configurable by Dip-Switch or PC Input: PTC/NTC, Potentiometer. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Channel : Yes |
| DAT4532D | Double channel, isolated converter for voltage and current configurable by Dip-Switch or PC Input: Volts and mA. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Channel : Yes |
| DAT4631A | Isolated Doubler/Converter for Tc and mV configurable by Dip-Switch or PC Input: Thermocouples and mV. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Output : Yes |
| DAT4631B | Isolated Doubler/Converter for RTD and resistance configurable by Dip-Switch or PC Input: RTD's. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Output : Yes |
| DAT4631C | Isolated, doubler/converter for PTC/NTC/Pot configurable by Dip-Switch or PC Input: PTC/NTC, Potentiometer. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Output : Yes |
| DAT4631D | Isolated doubler/converter for voltage and current configurable by Dip-Switch or PC Input: Volts and mA. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Output : Yes |
| DAT4632D | Isolated mathematical module for voltage and current input configurable by Dip-Switch or PC Input: Volts and mA. Output: Volts, mA. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC Dual Channel : Yes Option : Mathematical functions |
| DAT4540 |
Input: Frequency, Tacho, TTL, PNP, and Namur. Output: Volts, mA and 2 relay and Transistor. Power Supply: 20 - 30 Vdc Isolation : Yes Programmable : Dip Switch and PC |
Smart Series: Temperature and Signal Transmitters The SMART series devices can accept on their input several types of signals coming from the field.

| DAT2015 | Two wire universal transmitter Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples. Output: mA. Power Supply: Loop powered Isolation : No Programmable : No |
| DAT2015 IS/ HT | PC programmable Intrinsically safe two wire transmitter ATEX 94/9/CE Above with ATEX.
|
| DAT4035 | PC programmable two wire isolated universal transmitter Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples. Output: mA. Power Supply: Loop powered Isolation : Yes Programmable : PC |
| DAT4035 IS/HT | PC programmable isolated intrinsically safe two wire transmitter ATEX 94/9/CE As above with ATEX.
|
| DAT2115 | PC programmable Universal signal converter Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples. Output: Volts, mA. Power Supply: 18 - 30Vdc Isolation : No Programmable : Yes |
| DAT2115/SEL | PC programmable Universal signal converter with command of enable/disable output As above with a third terminal for selection. |
| DAT4135 | PC Programmable isolated universal signal converter Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples. Output: Volts, mA. Power Supply: 18 - 30Vdc Isolation : Yes Programmable : Yes |
| DAT4135/SEL | Isolated universal signal converter with command of enable/disable output As above with a third terminal for selection. |
| DAT4135AC | Isolated universal AC powered signal converter Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples. Output: Volts, mA. Power Supply: 90 - 250Vac Isolation : 3 way. Programmable : Yes |
| DAT4235 | PC Programmable 3 ways isolated universal signal converter Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples. Output: Volts, mA. Power Supply: 18 - 30Vdc Isolation : 3 way. Programmable : Yes |
| DAT4520 | PC Programmable Signal converter trip amplifier Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples. Output: Volts, mA and 2 relays. Power Supply: 18 - 30Vdc Isolation : 3 way. Programmable : Yes |
| DAT4235 IS | Signal Converter with Trip Amplifier for hazardous area Sensors ATEX 94/9/EC As above with ATEX. |
| DAT5030 IS | Hazardous area Current Loop repeater/supply ATEX 94/9/EC Input: mA. Output: mA. Power Supply: 18 - 30Vdc |
PDS Dip Switch Programmable Temperature and Signal Transmitters The P.D.S. (programmable by dip-switch)series transmitters and converters can accept on their input signals coming from 2 or 3 wires Pt100,Thermocouple and Strain Gauge sensors or Voltage and Current signals.

| DAT2065 | Programmable transmitter for Pt100 Input: RTD's. Output: mA. Power Supply: Loop Powered. Isolation : No. Programmable : Yes by Dip switch |
| DAT2066 | Dual channel programmable transmitter for Pt100 As above but Dual and Isolation between channels. |
| DAT2165 | Programmable converter for Pt100 Input: RTD's. Output: mA, Volts. Power Supply: 18 - 30Vdc. Isolation : No. Programmable : Yes by Dip switch |
| DAT2166 | Dual channel programmable converter for Pt100 As above but Dual and Isolation between channels. |
| DAT2061 | Isolated programmable converter for Pt100 Input: RTD's. Output: mA, Volts. Power Supply: 18 - 30Vdc. Isolation : Yes. Programmable : Yes by Dip switch |
| DAT2045 | Programmable transmitter for thermocouple Input: Thermocouples's. Output: mA. Power Supply: Loop Powered. Isolation : No. Programmable : Yes by Dip switch |
| DAT2145 | Programmable converter for thermocouple Input: Thermocouples's. Output: mA, Volts. Power Supply: 18 - 30Vdc. Isolation : No. Programmable : Yes by Dip switch |
| DAT5020 | 3 way isolated programmable signal converter Input: mA, Volts,and Pot. Output: Volts, mA. Power Supply: 18 - 32Vdc Isolation : Yes Programmable : Yes |
| DAT5021 | 3 way isolated programmable signal converter Input: mA, Volts. Output: Volts, mA. Power Supply: 18 - 32Vdc Isolation : Yes Programmable : Yes Special feature : Input and output can be Passive or Active. |
| DAT5022 | 4 way isolated programmable signal converter/signal splitter Input: mA, Volts. Output: Volts, mA. 2 Channels Power Supply: 18 - 32Vdc Isolation : Yes Programmable : Yes Special feature :Input and output can be Passive or Active. |
| DAT5023 I AC | Isolated programmable converter for AC current signal Input: AC Amps. Output: Volts, mA. Power Supply: 18 - 30Vdc Isolation : Yes Programmable : Yes |
| DAT5023 I DC | Isolated converter for DC current signal with fixed input, configurable output Input: DC Amps. Output: Volts, mA. Power Supply: 18 - 30Vdc Isolation : Yes Programmable : Yes |
| DAT5023V | 3 ways isolated programmable converter for AC/DC voltage signal Input: AC/DC Volts. Output: Volts, mA. Power Supply: 18 - 30Vdc Isolation : Yes Programmable : Yes |
| DAT5025 | Isolated programmable converter for Strain Gauge/Bridge sensors Input: Strain Gauge. Output: Volts, mA. Power Supply: 18 - 30Vdc Isolation : Yes Programmable : Yes |
Trip Amplifiers “DAT5024 SERIES”: TRIP AMPLIFIERS FOR DIN RAIL MOUNTING

| DAT5024 |
Input: mA, Volts,Resistance, RTD's, and Thermocouples. Output: 2 relays. Power Supply: 18 - 32Vdc Isolation : 3 way. Programmable : Yes |
| DAT5024/D | Configurable trip amplifier with display for the visualization of the trip level As above with display. |
| DAT5024E | Economic, isolated trip amplifier configurable by Dip-switches Input: mA, Volts. Output: 2 relays. Power Supply: 18 - 30Vdc Isolation : 3 way. Programmable : Yes |
| DAT5024/L | Low profile configurable trip amplifier As DAT5024 with enclosure size only 12.5 mm |
Data Acquisition and Control Modules DAT3000 The distributed I/O modules of the DAT3000 series represent a complete solution for the acquisition and control of the analog and digital I/O signals.

PLC A/D Interface modules DAT6000 The DAT6000 series devices are an evolution in the connection techniques of the analog signals to the PLC.

| DAT6011 | A/D interface for PLC 2 input channels for mV or Tc Inputs : 2 x mV, Thermocouples. Power supply : 18- 30 Vdc Communication : Digital to PLC Isolation : Yes |
| DAT6012 | A/D interface for PLC 2 input channels for RTD, Res. Inputs : 2RTD'S, Resistance. Power supply : 18- 30 Vdc Communication : Digital to PLC Isolation : Yes |
| DAT6013 | A/D interface for PLC 2 input channels for V, mA Inputs : 2 V, mA. Power supply : 18- 30 Vdc Communication : Digital to PLC Isolation : Yes |
| DAT6021 | A/D interface for PLC 4 input channels for mV, Tc Inputs : 2mV, Thermocouples. Power supply : 18- 30 Vdc Communication : Digital to PLC Isolation : Yes |
| DAT6023-I | A/D interface for PLC 4 input channels for Current Inputs : 4 mA. Power supply : 18- 30 Vdc Communication : Digital to PLC Isolation : Yes |
| DAT6023-V | A/D interface for PLC 4 input channels for Voltage Inputs : 4 V. Power supply : 18- 30 Vdc Communication : Digital to PLC Isolation : Yes |
Head Mount Temperature Transmitters DAT1000 The transmitters of the DAT1000 series can accept at their input signals coming from 2,3 or 4 wires Pt100,Thermocouple and potentiometer sensors or voltage signals (mV). The devices provide a 4÷20mA two wire current loop output signal. The series is composed of devices for fixed range, devices configurable by dip-switches and PC available in standard or low profile housing. The transmitters of the DAT1000 series configurable by PC can be provided in the versions with or without galvanic isolation. Moreover is available a version of the transmitters configurable by PC developed for use in potentially explosive atmospheres certified in accordance to the Directive ATEX 94/9/EC.

Panel Indicators The series of digital indicators is composed of instruments dedicated to the measure of temperature and process control signals.

| DAT701 | 3.5 digit LED digital indicator Input : mA, mV and V. Power Supply : 5 Vdc |
| DAT702 | 3.5 digit LCD digital indicator Input : mA, mV and V. Power Supply : 5 Vdc |
| DAT733 | Loop powered 3.5 digit LCD digital indicator Input : 4 -20mA. Power Supply : Loop Powered. |
| DAT734 | 3.5 digit LCD or LED display digit thermometer for Pt100 Input : RTD. Power Supply : 5 Vdc |
| DAT735 | 3.5 digit LCD or LED display digit thermometer for Thermocouple Input : Thermocouple. Power Supply : 5 Vdc |
| DAT8050 | Loop powered 4 digit LED programmable digital indicator Input : 4 -20mA. Power Supply : Loop Powered. |
Programmers and Software To program all the DATEXEL devices configurable by PC it is necessary to use dedicated software and to connect special programming interfaces between the devices and the PC.

| PRODAT-04 | RS232 Configuration interface for SMART and SLIM series devices |
| PRODAT USB | Configuration interface for SMART series devices for USB port |
Power supplies “DAT400 SERIES”: POWER SUPPLIES. The DAT400 series has been developed as integration of the signal converters and transmitters.

| DAT420 | Universal Switching Power Supply Unit with 24 Vdc @ 1A output Output : 24 Vdc 1 Amp. Power Supply : 100 - 250Vac |
| DAT411 | Double output power supply unit Output : 20 Vdc 25 mA x 2. Power Supply : 24 Vac,120 Vac,230 Vac. |
| DAT411R | Double regulated output power supply unit Output : 20 Vdc 30 mA x 2. Regulated Power Supply : 24 Vac,120 Vac,230 Vac. |