Complete product listing

Din Rail mount

Datexel manufactures the largest range of din rail mountable signal conditioners, head mount and din rail temperature transmitters, isolators and trip amplifiers.

The units can be fixed range, dip switch programmable or pc programmable.

Signal Converters Fixed Low Cost

Signal Converters Dip Switch Programmable

Signal Converters and Transmitter "Slim Line"

Signal Converters and Transmitter "Smart Line"

Loop Powered Isolators

Trip Amplifiers

Panel Indicators

PLC Input Modules

Modbus I/O Modules

Programmers

Signal Converters DAT200 The DAT200 series of transmitters and converters can accept input signals from potentiometers, voltage or current signals. The 2 wire is loop powered and 3 wire has a voltage or current output.

Dat200 Converter

Back to top of the page

DAT205 2W

2Wire Loop Powered Converter for Potentiometer.

Input: Potentiometer

Output: 4-20 mA

Power Supply: Loop

DAT205 3W

3 Wire Voltage, Current output. Potentiometer input.

Input: Potentiometer

Output: Voltage or 4-20mA

Power Supply: 18 -30 Vdc

DAT207A 2W

2Wire Loop Powered Converter for mV.

Input: mV.

Output: 4-20 mA

Power Supply: Loop

DAT207A 3W

3 Wire Voltage, Current output. Voltage, Current input.

Input: mV.

Output: Voltage or 4-20mA

Power Supply: 18 -30 Vdc

DAT207B 2W

2Wire Loop Powered Converter for mV.

Input: mV, or Volts.

Output: 4-20 mA

Power Supply: Loop

DAT207B 3W

3 Wire Voltage, Current output. Voltage, Current input.

Input: mV, or Volts.

Output: Voltage or 4-20mA

Power Supply: 18 - 30 Vdc

DAT207C 2W

2Wire Loop Powered Converter for mV.

Input: mA.

Output: 4-20 mA

Power Supply: Loop

DAT207C 3W

3 Wire Voltage, Current output. Voltage, Current input.

Input: mA.

Output: Voltage or 4-20mA

Power Supply: 18 - 30 Vdc

Loop Powered Isolator DAT511 The DAT500 series of self-powered galvanic isolators provide isolation between grounds. The DAT511H is suitable for Hart applications.

DAT511 Hart Isolator

Back to top of the page

DAT511

Self Powered Loop Isolator.

Input: mA.

Output: 4-20 mA

Power Supply: Loop

DAT511H

Self Powered Loop Isolator. Suitable for HART applications.

Input: mA.

Output: 4-20 mA

Power Supply: Loop

Slim Series: Temperature and Signal Converters The new line of converters that provides the highest flexibility in signal conversion.

DAT4530 Signal conditioner

Back to top of the page

DAT4530

Universal isolated converter configurable by dip-switch or PC double output & trip amplifier.
Option of SQRT Extraction on mV, V, mA input signals.

Input: mA, Volts,Resistance, RTD's, and Thermocouples.

Output: Volts, mA, Relay.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Trip Amp : Yes

Square Root Extraction : Yes

Programmable : Dip Switch and PC

Dual Output : Yes

DAT4531A

Isolated converter for Tc and mV configurable by Dip-Switch or PC

Input: Thermocouples and mV.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

DAT4531B

Isolated converter for RTD and resistance configurable by Dip-Switch or PC

Input: RTD's.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

DAT4531C

Isolated converter for PTC/NTC/Pot configurable by Dip-Switch or PC

Input: PTC/NTC, Potentiometer.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

DAT4531D

Isolated converter for voltage and current configurable by Dip-Switch or PC

Input: Volts and mA.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

DAT4532A

Double channel, isolated converter for Tc and mV configurable by Dip-Switch or PC

Input: Thermocouples and mV.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Channel : Yes

DAT4532B

Double channel, isolated converter for RTD and resistance configurable by Dip-Switch or PC

Input: RTD's.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Channel : Yes

DAT4532C

Isolated, double channel converter for PTC/NTC/Pot configurable by Dip-Switch or PC

Input: PTC/NTC, Potentiometer.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Channel : Yes

DAT4532D

Double channel, isolated converter for voltage and current configurable by Dip-Switch or PC

Input: Volts and mA.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Channel : Yes

DAT4631A

Isolated Doubler/Converter for Tc and mV configurable by Dip-Switch or PC

Input: Thermocouples and mV.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Output : Yes

DAT4631B

Isolated Doubler/Converter for RTD and resistance configurable by Dip-Switch or PC

Input: RTD's.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Output : Yes

DAT4631C

Isolated, doubler/converter for PTC/NTC/Pot configurable by Dip-Switch or PC

Input: PTC/NTC, Potentiometer.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Output : Yes

DAT4631D

Isolated doubler/converter for voltage and current configurable by Dip-Switch or PC

Input: Volts and mA.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Output : Yes

DAT4632D

Isolated mathematical module for voltage and current input configurable by Dip-Switch or PC

Input: Volts and mA.

Output: Volts, mA.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Dual Channel : Yes

Option : Mathematical functions

DAT4540

Isolated Frequency to Voltage, Frequency to Current Converter Configurable by Dip-Switch or PC Transistors or Relay Outputs

Input: Frequency, Tacho, TTL, PNP, and Namur.

Output: Volts, mA and 2 relay and Transistor.

Power Supply: 20 - 30 Vdc

Isolation : Yes

Programmable : Dip Switch and PC

Smart Series: Temperature and Signal Transmitters The SMART series devices can accept on their input several types of signals coming from the field.

DAT5030 Current loop repeater

Back to top of the page

DAT2015

Two wire universal transmitter

Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : No

DAT2015 IS/ HT

PC programmable Intrinsically safe two wire transmitter ATEX 94/9/CE

Above with ATEX.

 

DAT4035

PC programmable two wire isolated universal transmitter

Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples.

Output: mA.

Power Supply: Loop powered

Isolation : Yes

Programmable : PC

DAT4035 IS/HT

PC programmable isolated intrinsically safe two wire transmitter ATEX 94/9/CE

As above with ATEX.

 

DAT2115

PC programmable Universal signal converter

Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples.

Output: Volts, mA.

Power Supply: 18 - 30Vdc

Isolation : No

Programmable : Yes

DAT2115/SEL

PC programmable Universal signal converter with command of enable/disable output

As above with a third terminal for selection.

DAT4135

PC Programmable isolated universal signal converter

Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples.

Output: Volts, mA.

Power Supply: 18 - 30Vdc

Isolation : Yes

Programmable : Yes

DAT4135/SEL

Isolated universal signal converter with command of enable/disable output

As above with a third terminal for selection.

DAT4135AC

Isolated universal AC powered signal converter

Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples.

Output: Volts, mA.

Power Supply: 90 - 250Vac

Isolation : 3 way.

Programmable : Yes

DAT4235

PC Programmable 3 ways isolated universal signal converter

Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples.

Output: Volts, mA.

Power Supply: 18 - 30Vdc

Isolation : 3 way.

Programmable : Yes

DAT4520

PC Programmable Signal converter trip amplifier

Input: mA, Volts,Resistance, RTD's, Pot and Thermocouples.

Output: Volts, mA and 2 relays.

Power Supply: 18 - 30Vdc

Isolation : 3 way.

Programmable : Yes

DAT4235 IS

Signal Converter with Trip Amplifier for hazardous area Sensors ATEX 94/9/EC

As above with ATEX.

DAT5030 IS

Hazardous area Current Loop repeater/supply ATEX 94/9/EC

Input: mA.

Output: mA.

Power Supply: 18 - 30Vdc

PDS Dip Switch Programmable Temperature and Signal Transmitters The P.D.S. (programmable by dip-switch)series transmitters and converters can accept on their input signals coming from 2 or 3 wires Pt100,Thermocouple and Strain Gauge sensors or Voltage and Current signals.

DAT2065 Temerature transmitter

Back to top of the page

DAT2065

Programmable transmitter for Pt100

Input: RTD's.

Output: mA.

Power Supply: Loop Powered.

Isolation : No.

Programmable : Yes by Dip switch

DAT2066

Dual channel programmable transmitter for Pt100

As above but Dual and Isolation between channels.

DAT2165

Programmable converter for Pt100

Input: RTD's.

Output: mA, Volts.

Power Supply: 18 - 30Vdc.

Isolation : No.

Programmable : Yes by Dip switch

DAT2166

Dual channel programmable converter for Pt100

As above but Dual and Isolation between channels.

DAT2061

Isolated programmable converter for Pt100

Input: RTD's.

Output: mA, Volts.

Power Supply: 18 - 30Vdc.

Isolation : Yes.

Programmable : Yes by Dip switch

DAT2045

Programmable transmitter for thermocouple

Input: Thermocouples's.

Output: mA.

Power Supply: Loop Powered.

Isolation : No.

Programmable : Yes by Dip switch

DAT2145

Programmable converter for thermocouple

Input: Thermocouples's.

Output: mA, Volts.

Power Supply: 18 - 30Vdc.

Isolation : No.

Programmable : Yes by Dip switch

DAT5020

3 way isolated programmable signal converter

Input: mA, Volts,and Pot.

Output: Volts, mA.

Power Supply: 18 - 32Vdc

Isolation : Yes

Programmable : Yes

DAT5021

3 way isolated programmable signal converter

Input: mA, Volts.

Output: Volts, mA.

Power Supply: 18 - 32Vdc

Isolation : Yes

Programmable : Yes

Special feature : Input and output can be Passive or Active.

DAT5022

4 way isolated programmable signal converter/signal splitter

Input: mA, Volts.

Output: Volts, mA. 2 Channels

Power Supply: 18 - 32Vdc

Isolation : Yes

Programmable : Yes

Special feature :Input and output can be Passive or Active.

DAT5023 I AC

Isolated programmable converter for AC current signal

Input: AC Amps.

Output: Volts, mA.

Power Supply: 18 - 30Vdc

Isolation : Yes

Programmable : Yes

DAT5023 I DC

Isolated converter for DC current signal with fixed input, configurable output

Input: DC Amps.

Output: Volts, mA.

Power Supply: 18 - 30Vdc

Isolation : Yes

Programmable : Yes

DAT5023V

3 ways isolated programmable converter for AC/DC voltage signal

Input: AC/DC Volts.

Output: Volts, mA.

Power Supply: 18 - 30Vdc

Isolation : Yes

Programmable : Yes

DAT5025

Isolated programmable converter for Strain Gauge/Bridge sensors

Input: Strain Gauge.

Output: Volts, mA.

Power Supply: 18 - 30Vdc

Isolation : Yes

Programmable : Yes

Trip Amplifiers “DAT5024 SERIES”: TRIP AMPLIFIERS FOR DIN RAIL MOUNTING

DAT2065 Temerature transmitter

Back to top of the page

DAT5024

Configurable trip amplifier

Input: mA, Volts,Resistance, RTD's, and Thermocouples.

Output: 2 relays.

Power Supply: 18 - 32Vdc

Isolation : 3 way.

Programmable : Yes

DAT5024/D

Configurable trip amplifier with display for the visualization of the trip level

As above with display.

DAT5024E

Economic, isolated trip amplifier configurable by Dip-switches

Input: mA, Volts.

Output: 2 relays.

Power Supply: 18 - 30Vdc

Isolation : 3 way.

Programmable : Yes

DAT5024/L

Low profile configurable trip amplifier

As DAT5024 with enclosure size only 12.5 mm

Data Acquisition and Control Modules DAT3000 The distributed I/O modules of the DAT3000 series represent a complete solution for the acquisition and control of the analog and digital I/O signals.

Back to top of the page

DAT3580

Isolated converter RS232 to RS485, RS232 to RS422

Communication : RS485, RS422, and RS232

Power Supply : 10 - 30 Vdc or 9 - 18 Vac

Isolation : Yes

DAT3580-USB

Isolated converter USB to RS485 USB to RS422

Communication : USB to RS485 USB to RS422

Power Supply : 10 - 30 Vdc or 9 - 18 Vac

Isolation : Yes

DAT3580-MBTCP

Ethernet Gateway Modbus TCP Modbus RTU

Communication : Modbus TCP - Modbus RTU

Power Supply : 10 - 30 Vdc or 9 - 18 Vac

Isolation : Yes

DAT3590

Repeater and Isolator RS485, Repeater and Isolator RS422

Communication : RS485 - RS422

Power Supply : 10 - 30 Vdc or 9 - 18 Vac

Isolation : Yes

DAT3130

Distributed I/O Module 4 digital inputs + 4 relay outputs on RS-485 network

Inputs : 4 Digital inputs

Outputs : 4 Relays

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3140

Distributed I/O Module 4 digital inputs + 8 NPN outputs on RS-485 network

Inputs : 4 Digital inputs

Outputs : 8 NPN

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3148/8

Distributed I/O Module 8 digital inputs on RS-485 network

Inputs : 8 Digital inputs

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3148/12

Distributed I/O Module 8 + 4 digital inputs on RS-485 network

Inputs : 12 Digital inputs

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3188/4

Distributed I/O Module 4 digital inputs + 8 PNP outputs on RS-485 network

Inputs : 4 Digital inputs

Outputs : 8 PNP

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3188/8

Distributed I/O Module 8 digital inputs + 8 PNP outputs on RS-485 network

Inputs : 8 Digital inputs

Outputs : 8 PNP

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3010

Remote I/O module universal input on RS-485 network

Input : Thermocouples, RTD, Voltage, Resistance, mA, Digital.

Outputs : 2 Digital output.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3014

Remote I/O module 4 channel RTD input on RS-485 network

Inputs : 4 RTD, Resistance, Potentiometer.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3015-I

Remote I/O module 4 channel +/-20 mA input on RS-485 network

Inputs : 4 mA.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3015-V

Remote I/O module 4 channel +/-10 V input con RS-485 network

Inputs : 4 Volts.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3016

Remote I/O module 4 channel mV, Tc input on RS-485 network

Inputs : 4 mV, Thermocouples.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3017-I

Remote I/O module 8 channel +/-20 mA input on RS-485 network

Inputs : 8 mA.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3017-V

Remote I/O module 8 channel +/-10 V input on RS-485 network

Inputs : 8 Volts.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3018

Remote I/O module 8 channel mV, Tc input on RS-485 network

Inputs : 8 mV, Thermocouples.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3019

Remote I/O module 8 channel RTD input on RS-485 network

Inputs : 8 RTD.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

 

DAT3022

Remote I/O module 2 channel V/mA output on RS-485 network

Outputs : 2 mA, Volts.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3024

Remote I/O module 4 channel V/mA output on RS-485 network

Outputs : 4 mA, Volts.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

DAT3028

Remote I/O module 8 channel 0-10 V output on RS-485 network

Outputs : 8 Volts.

Power supply : 18- 30 Vdc

Communication : RS485

Isolation : Yes

PLC A/D Interface modules DAT6000 The DAT6000 series devices are an evolution in the connection techniques of the analog signals to the PLC.

Back to top of the page

DAT6011

A/D interface for PLC 2 input channels for mV or Tc

Inputs : 2 x mV, Thermocouples.

Power supply : 18- 30 Vdc

Communication : Digital to PLC

Isolation : Yes

DAT6012

A/D interface for PLC 2 input channels for RTD, Res.

Inputs : 2RTD'S, Resistance.

Power supply : 18- 30 Vdc

Communication : Digital to PLC

Isolation : Yes

DAT6013

A/D interface for PLC 2 input channels for V, mA

Inputs : 2 V, mA.

Power supply : 18- 30 Vdc

Communication : Digital to PLC

Isolation : Yes

DAT6021

A/D interface for PLC 4 input channels for mV, Tc

Inputs : 2mV, Thermocouples.

Power supply : 18- 30 Vdc

Communication : Digital to PLC

Isolation : Yes

DAT6023-I

A/D interface for PLC 4 input channels for Current

Inputs : 4 mA.

Power supply : 18- 30 Vdc

Communication : Digital to PLC

Isolation : Yes

DAT6023-V

A/D interface for PLC 4 input channels for Voltage

Inputs : 4 V.

Power supply : 18- 30 Vdc

Communication : Digital to PLC

Isolation : Yes

Head Mount Temperature Transmitters DAT1000 The transmitters of the DAT1000 series can accept at their input signals coming from 2,3 or 4 wires Pt100,Thermocouple and potentiometer sensors or voltage signals (mV). The devices provide a 4÷20mA two wire current loop output signal. The series is composed of devices for fixed range, devices configurable by dip-switches and PC available in standard or low profile housing. The transmitters of the DAT1000 series configurable by PC can be provided in the versions with or without galvanic isolation. Moreover is available a version of the transmitters configurable by PC developed for use in potentially explosive atmospheres certified in accordance to the Directive ATEX 94/9/EC.

Head mount temperature transmitter

Back to top of the page

DAT1040

Fixed range linearised transmitter for Pt100

Two wire universal transmitter

Input: RTD's.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : No

DAT1030

Fixed range transmitter for Thermocouple

Two wire universal transmitter

Input: Thermocouple.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : No

DAT1111F

Low profile fixed range linearised transmitter for Pt100

Two wire universal transmitter

Input: RTD's.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : No

DAT1112F

Low profile fixed range transmitter for Thermocouple

Two wire universal transmitter

Input: Thermocouple.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : No

DAT1110

Dip Switch programmable and linearised transmitter for Pt100

Two wire universal transmitter

Input: RTD's.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes Dip Switch

DAT1120

Dip Switch programmable transmitter for Thermocouple

Two wire universal transmitter

Input: Thermocouple.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes Dip Switch

 

DAT1111

Dip Switch low profile programmable and linearised transmitter Pt100

Two wire universal transmitter

Input: RTD's.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes Dip Switch

DAT1112

Dip Switch low profile programmable transmitter for Thermocouple

Two wire universal transmitter

Input: Thermocouple.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes Dip Switch

 

DAT1010

Two wire transmitter for RTD Programmable by Personal Computer

Two wire universal transmitter

Input: RTD's.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes PC

DAT1010IS/HT

Intrinsically safe two wire transmitter for RTD Programmable by pc

Above with ATEX

DAT1015

Two wire universal transmitter Programmable by pc

Two wire universal transmitter

Input: Thermocouple,RTD's Pot and mV.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes PC

DAT1015IS/HT

Intrinsically safe two wire universal transmitter Programmable by pc

Above with ATEX

DAT1070

Low profile two wire transmitter for RTD Programmable by PC

Two wire universal transmitter

Input: RTD's Pot and mV.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes PC

DAT1075

Low profile two wire transmitter Programmable by PC

Two wire universal transmitter

Input: Thermocouple, RTD, mV, Resistance.

Output: mA.

Power Supply: Loop powered

Isolation : No

Programmable : Yes PC

DAT1060

Isolated two wire transmitter for RTD Programmable by PC

Two wire universal transmitter

Input: RTD's, mV, Potentiometer, Resistance.

Output: mA.

Power Supply: Loop powered

Isolation : Yes

Programmable : Yes PC

DAT1065

Isolated two wire universal transmitter Programmable by PC

Two wire universal transmitter

Input: Thermocouple, RTD, mV, Potentiometer, Resistance.

Output: mA.

Power Supply: Loop powered

Isolation : Yes

Programmable : Yes PC

DAT1065IS/HT

Isolated intrinsically safe two wire transmitter Programmable by PC

As above with ATEX

Panel Indicators The series of digital indicators is composed of instruments dedicated to the measure of temperature and process control signals.

Back to top of the page

DAT701

3.5 digit LED digital indicator

Input : mA, mV and V.

Power Supply : 5 Vdc

DAT702

3.5 digit LCD digital indicator

Input : mA, mV and V.

Power Supply : 5 Vdc

DAT733

Loop powered 3.5 digit LCD digital indicator

Input : 4 -20mA.

Power Supply : Loop Powered.

DAT734

3.5 digit LCD or LED display digit thermometer for Pt100

Input : RTD.

Power Supply : 5 Vdc

DAT735

3.5 digit LCD or LED display digit thermometer for Thermocouple

Input : Thermocouple.

Power Supply : 5 Vdc

DAT8050

Loop powered 4 digit LED programmable digital indicator

Input : 4 -20mA.

Power Supply : Loop Powered.

Programmers and Software To program all the DATEXEL devices configurable by PC it is necessary to use dedicated software and to connect special programming interfaces between the devices and the PC.

Programmers and Software

Back to top of the page

PRODAT-04 RS232 Configuration interface for SMART and SLIM series devices
PRODAT USB Configuration interface for SMART series devices for USB port

Power supplies “DAT400 SERIES”: POWER SUPPLIES. The DAT400 series has been developed as integration of the signal converters and transmitters.

Back to top of the page

DAT420

Universal Switching Power Supply Unit with 24 Vdc @ 1A output

Output : 24 Vdc 1 Amp.

Power Supply : 100 - 250Vac

DAT411

Double output power supply unit

Output : 20 Vdc 25 mA x 2.

Power Supply : 24 Vac,120 Vac,230 Vac.

DAT411R

Double regulated output power supply unit

Output : 20 Vdc 30 mA x 2. Regulated

Power Supply : 24 Vac,120 Vac,230 Vac.