Thermocouple LCD or LED digital display.Thermocouple LCD or LED digital display.

Thermocouple LCD or LED digital display.

FEATURES

- Input for Thermocouple sensors type E, K, J, N, S and T

Visualisation on LCD or LED display

High accuracy

Measure freezing by command

Low current consumption

EMC compliant - CE mark

DIN 36 x 72 mm housing

Mounting on panel according to DIN 43700 standard

 

 

 

 

 

 

Click here to request Information.

Thermocouple LCD or LED digital display.

Thermocouple LCD or LED digital display.

 

 

 

 

 

 

 

 

 

 

 

 

Thermocouple Digital Indicator DAT735 LCD or LED

GENERAL DESCRIPTION

The DATEXEL DAT735 is a 3.5 digit LCD or LED digital indicator with high accuracy and reliability able to measure Temperature from a Thermocouple probe.

The DATEXEL DAT735 is designed for mounting in a panel in accordance with DIN 43700 standards .

The zero and span can be adjusted with potentiometers located on the rear of the DATEXEL DAT735.

The DATEXEL DAT735 is designed for mounting in a panel in accordance with DIN 43700 standards. It also has a function to freeze (HOLD) the display.

The DATEXEL DAT735 is in compliance with the directive CEE/336/89 on the Electromagnetic Compatibility.

USER INSTRUCTIONS

The digital thermometer DATEXEL DAT735 must be connected as follows.

Connect the power supply between the terminals T3 (+V) and T2 (GND); in order to avoid damages for the device, the power supply value must be lower than 5.5 Vdc.

The input sensor must be connected between the terminals T4 (+Tc) and T5 (-Tc).

The complementary function HOLD could be used to freeze the measure at the last value detected. To use this function connect the terminal

T1 (HOLD) to the terminal T2 (GND); in order to avoid damages for the device, it is recommended to active this function for a maximum time
of 2 minutes.

To calibrate and install the device refer to sections “Calibration DATEXEL DAT735” and “Installation Instructions”.

TECHNICAL SPECIFICATIONS

thermocouple-indicator

INSTALLATION INSTRUCTIONS

The DATEXEL DAT735 is suitable for mounting on panel (DIN 43700); the device needs a panel cut out of 68 * 33 mm (W*H).

It is necessary to install the device in a place without vibrations; avoid to routing conductors near power signal cables .

DIMENSIONS (mm)

k-type-indicator

CONNECTIONS

thermocouple-panel-indicator

 

CALIBRATION

Refer to section “Dimensions and Regulations”.

1) Connect on input a Thermocouple simulator.

2) Set the simulator at the minimum value of the input range.

3) By the ZERO potentiometer, adjust the minimum value of visualisation.

4) Set the simulator at the maximum value of the input range.

5) By the SPAN potentiometer, adjust the maximum value of
visualisation.

CUT OUT

temperature-thermocouple-indicator