DAT410 Double output power supply unit.
GENERAL DESCRIPTION
The power supply unit DAT410 is designed to provide two none regulated galvanic isolated outputs to power the DATEXEL devices like transmitters and low current consumption converters.
The device can accept three input voltage values:24, 120 or 230 Vac.
The DAT 410 is in compliance with the standard 89/336/EEC on the Electromagnetic Compatibility.
It is housed in a plastic enclosure of 22 mm thickness suitable for DIN rail mounting in compliance with EN-50022 and EN-50035 standards.
USER INSTRUCTIONS
The DAT410 must be connected as follows:
The input connections must be made as shown in the section "Input connections".
The input voltage ( AC line ) must be applied between the terminals G ( IN AC) and H ( IN AC ).
The output connections must be made as shown in the sections “Output 1 & 2 connections”
The output signal Out 1 is provided between the terminals F (+Vout1) and E (GND1),
The output signal Out 2 is provided between the terminals D (+Vout2) and C (GND2).
To install the transmitter refer to section “Installation Instructions”.
TECHNICAL SPECIFICATIONS
| Input | |
| Input voltage | |
| Outputs | |
| Output 1 (Out 1) |
20 Vdc @ 30 mA not regulated |
| Output 2 (Out 2) | 10 Vdc @ 10 mA not regulated |
| Load resistance (Rload) | see section “Load characteristic” |
| Environmental data Safety |
EN 61010-1 |
| Electromagnetic Compatibility (EMC) ( for industrial environments ) Immunity: |
EN 61000-6-2; Emission : EN 61000-6-4. |
| Operating Temperature | -20 ÷ 60 °C |
| Storage Temperature | -40 ÷ 85 °C |
| Humidity (not condensed) | 0 ÷ 90% |
| Weight about | 110 g |
Dimensions (mm)

Connections