Universal signal converter.DAT2115 Universal signal converter.

FEATURES

Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer

Configurable output in current or voltage

Configurable by Personal Computer

High accuracy

On-field reconfigurable

EMC compliant – CE mark

Suitable for DIN rail mounting in compliance with EN-50022 and EN50035

 

 

 

 

 

 

Call Toll Free for more Information

1 877 4to 20mA

1 877 486 2062

24/7 Support

1 225 200 7419

Click here to request Information.

 

DAT2115 Universal signal converter.

DAT2115 Universal signal converter.

 

 

 

 

 

 

 

 

 

 

 

 

Universal input Converter the DAT2115 with PC programmability.

GENERAL DESCRIPTION

The universal Converter DAT2115 is a Din Rail mount temperature/signal Converter with PC programmability. The input can be thermocouples, RTD, mA, V, mV, resistance and potentiometer. The DAT2115 will linearize the temperature input and provide a 4-20mA or voltage output signal.

The DAT2115 is accurate to 0.1% full scale and has less than 0.01%/'f thermal drift.

The DAT2115 is programmable by PC based software which has been developed by DATEXEL to be user friendly.

For resistance and RTD's sensors it is possible to program the cable compensation for 3 or 4 wires.

It is possible to set the minimum and maximum values of the input and output ranges in any point of the scale, keeping the minimum span shown in the table below. Also high burn out alarm or low burn out alarm is selectable.

The DAT2115 is in compliance with the standard 89/336/CEE on the Electromagnetic Compatibility.

The DAT2115 is housed in a plastic enclosure of 12.5 mm thickness suitable for DIN rail mounting in compliance with EN-50022 and EN-50035 standards.

The DAT2115 is able to measure and linearize the standard thermocouples with internal cold junction compensation.

Suitable for the following thermocouples.

K Type Thermocouples

J Type Thermocouples

S Type Thermocouples

R Type Thermocouples

B Type Thermocouples

E Type Thermocouples

T Type Thermocouples

N Type Thermocouples

Suitable for the following RTD.

Pt100

Pt1000

Ni100

Ni1000

 

USER INSTRUCTIONS

The converter DAT2115 must be powered by a direct voltage between 18 to 30 V applied to the terminals R(+Vdc) and Q (GND) as shown in the section "Power supply connections".

The output signal, in voltage or current, is provided to the terminals N(OUT) and M (GND), as shown in the section "Output connections".

The input connections must be made as shown in the section "Input connections".

To configure, calibrate and install the converter, refer to sections " DAT2115: configuration and calibration" and “Installation Instructions”.

TECHNICAL SPECIFICATIONS

DAT2115-transmitter

mulitply-input-transmitter

 

INSTALLATION INSTRUCTIONS

The device DAT2115 is suitable for DIN rail mounting. It is necessary to install the device in a place without vibrations; avoid to routing conductors near power signal cables .